| ||||||||||||
| ||||||||||||
| M52 | ||||||||||||
| Installation diagram (M52) for Master F 1 Connect Direct fixing plate F 0152, installed at 600 mm centres (for use in concrete) 2 Connect Anchor screw 4000, installed at 600 mm centres (for use in concrete) 3 Connect Installation screw 4057, fixed at 200 mm centres (for use in plasterboard or timber) 4 Connect Spline F 0160, L=600 mm. Must be used in Sweden, Denmark, Norway and Finland at fireclass "Tändskyddande beklädnad" 5 Connect Spline 0219, L=150 mm 6 Connect Wall spring spacer 0087 7 Connect Angle trim, fixed at 300 mm centres 8 For use when installing floating ceilings: Connect Wood trim 2141, L=3000, fixed at 500 mm centres 9 Timber installed at 600 mm centres (300 mm if thermal insulation is placed above), with the screw fixings along the timber. Min. overall depth of system: 40 mm Min. demounting depth: The system is non-demountable Download
| ||||||||||||